Analysis of jaw electromagnetic clutch installation matters needing attention
Release time:
2021-06-06
When installing the jaw electromagnetic clutch, there must be a certain gap between the teeth on the end face to avoid tooth wear when idling, but not exceed a certain value. Let's learn about the precautions for the installation of the jaw electromagnetic clutch!
When installing the jaw electromagnetic clutch, there must be a certain gap between the teeth on the end face to avoid tooth wear when idling, but not exceed a certain value. Let's learn about the precautions for the installation of the jaw electromagnetic clutch!

1. The electromagnetic clutch and brake are Class B insulation, the coil and friction parts are easily damaged, the normal temperature rises by 40, and the working temperature during thermal balance shall not exceed 100.
2. The power supply, control circuit and clutch power supply are usually 24 volts DC, which are obtained by step-down full-wave rectification of three-phase or single-phase AC voltage. Stability and filtering are not required. The power of the power supply is more than 1.5 times the rated power of the electromagnetic clutch.
Installation notes:
1. Please use the dry electromagnetic clutch without moisture, oil, etc. If moisture and oil are attached to the friction part, the friction torque will be greatly reduced. Therefore, in use, in order to avoid these situations, please install a cover.
2, please use the protective cover, when used in dusty places.
3. When installing the shaft, please use one of the keys specified in the JIS B1301-1959. For the long shaft size of the installation clutch, please use the standard JIS0401 H6 or JS6.
4. Please control the thrust of the installation shaft below 0.2MM, taking into account factors such as thermal expansion.
5. Please mechanically adjust the suction clearance within plus or minus 20% of the specified value for installation.
6. Please keep the bracket gently and do not suffer excessive pressure due to the bearing of the clutch.
7. Please use spring metal sheet, adhesive, etc. to prevent loosening. About the screws used for assembly.
8, with the mechanical side of the frame to maintain the wire at the same time, with the terminal plate and other reliable connection.
Maintenance and maintenance methods In order to ensure the continuous operation of the electromagnetic clutch, maintenance and maintenance must be carried out frequently:
1. Add more lubricant to the movable part of the electromagnetic clutch.
2. Check the stroke length of the armature regularly. This is because when the clutch is running, the wear of the section will increase the stroke length of the armature. It needs to be adjusted to restore the small gap between the braking surface and the turntable. When the stroke length does not reach the normal value, if the stroke length of the armature is above the normal value, the attraction force may be greatly reduced.
The above introduction is the jaw electromagnetic clutch installation precautions, if you need to know more, you can contact us at any time!
Key words:
Jaw electromagnetic clutch, jaw electromagnetic clutch manufacturers
recommend News
The role of electromagnetic brake
2022-10-28
Regarding the difference between energized brakes and non-energized electromagnetic brakes, many users do not know the working principle of these two electromagnetic brakes and the difference between the two. Then, let's learn about the role of electromagnetic brakes!
Introduction and Application of Electromagnetic Brake
2022-10-18
Electromagnetic brakes are mainly matched with series motors and are widely used in the metallurgical industry. Construction. The chemical industry. Food. Machine tools. Phase. The elevator. Vessels. Packaging machinery and braking in the event of electrical failure.
The working principle of electromagnetic brake
2022-10-09
The electromagnetic brake is a connector that transmits torque from the active side to the passive side. Any combination of cutting or braking can be required. The electromagnetic brake has compact structure, simple operation, sensitive response and easy to realize remote control.
The company has a product research and development department composed of experts, senior engineers and other professional and technical personnel. It is engaged in research and development and has perfect research and development test equipment. At present, the products reach more than 100 series of nearly 1,000 specifications, and the force distance ranges from 0.1N. m ~ 250000N.m. The company has been rated as a high-tech enterprise by the state for more than ten consecutive years, and a number of R & D projects have been established locally and have received municipal financial support.
Service Hotline:
Sales Department: Xu Jie
Sales Phone:+86-22-26616372, +86-22-26341260, +86 13920613215
Fax: 86-022-26616580
Market Development Department: Li Shuo
Marketing Department Telephone:+86-22-26614130
Technology Department: Yue Chao
Technical Department Telephone:+86-22-26222775 ,+86 18602228435
QQ:1059237223 1611412939
Company Website:www.tjlhq.com
Enterprise E-mail:xzm@tjlhq.com