Fault types of small electromagnetic clutches


Release time:

2021-09-13

Small electromagnetic clutch faults generally occur during starting, idling and loading, but they often occur during starting, mainly because they cannot be started or the input voltage of the small electromagnetic clutch is too low. regular input voltage is DC24V. As well as unstable power supply, slippage or high temperature. However, there are special circumstances, so pay attention to the requirements when inputting voltage. The troubleshooting method is to check whether the input voltage is the voltage required by the small electromagnetic clutch. The coil is short-circuited, and this failure usually needs to be replaced or repaired. It is recommended to modify the small electromagnetic clutch circuit that is replaced or modified.

Small electromagnetic clutch faults generally occur during starting, idling and loading, but they often occur during starting, mainly because they cannot be started or the input voltage of the small electromagnetic clutch is too low. regular input voltage isDC24V. And unstable power supply, slippage or high temperature, etc. However, there are special circumstances, so pay attention to the requirements when inputting voltage. The troubleshooting method is to check whether the input voltage is the voltage required by the small electromagnetic clutch. The coil is short-circuited, and this failure usually needs to be replaced or repaired. It is recommended to modify the small electromagnetic clutch circuit that is replaced or modified.

小型电磁离合器

  Unstable operation. It is likely that the input voltage is unstable. The power of the detection power supply is greater than the rated power of the small electromagnetic clutch1.5Times or so, the voltage fluctuations in-5%Within. The solution to unstable operation is to check the voltage and stabilize the voltage. Another case is friction heating, the coil is burned or short-circuited due to heat.

  The basic use of small electromagnetic clutch

  1, Connection and disconnection action: If a clutch is installed between the driving part and the starting part, there is no need to stop the driving part. The starting part will switch on and off according to the necessary reaction.

  2Variable speed: There is a mutual variable speed during operation. At this time, when the clutch is used, the speed can be changed without turning off the drive.

  3, forward and reverse rotation: when the load point is switched between forward and reverse rotation, if used with the clutch, only forward rotation is required.

  4High-frequency operation: intermittent operation in rapid cycle, repeated use of the motorONandOFFProvides limited frequency, so the clutch is used to make it react quickly and brake with high accuracy.

  5, Inching: When the machine starts to move and engages the position, just start the clutch instantly.


Key words:

Electromagnetic clutch, small electromagnetic clutch


recommend News


The role of electromagnetic brake

2022-10-28

Regarding the difference between energized brakes and non-energized electromagnetic brakes, many users do not know the working principle of these two electromagnetic brakes and the difference between the two. Then, let's learn about the role of electromagnetic brakes!

Introduction and Application of Electromagnetic Brake

2022-10-18

Electromagnetic brakes are mainly matched with series motors and are widely used in the metallurgical industry. Construction. The chemical industry. Food. Machine tools. Phase. The elevator. Vessels. Packaging machinery and braking in the event of electrical failure.

The working principle of electromagnetic brake

2022-10-09

The electromagnetic brake is a connector that transmits torque from the active side to the passive side. Any combination of cutting or braking can be required. The electromagnetic brake has compact structure, simple operation, sensitive response and easy to realize remote control.

Tianjin Lingjie Transmission

The company has a product research and development department composed of experts, senior engineers and other professional and technical personnel. It is engaged in research and development and has perfect research and development test equipment. At present, the products reach more than 100 series of nearly 1,000 specifications, and the force distance ranges from 0.1N. m ~ 250000N.m. The company has been rated as a high-tech enterprise by the state for more than ten consecutive years, and a number of R & D projects have been established locally and have received municipal financial support.

Service Hotline:

Sales Department: Xu Jie

Sales Phone:+86-22-26616372+86-22-26341260+86 13920613215

Fax: 86-022-26616580
Market Development Department: Li Shuo

Marketing Department Telephone:+86-22-26614130

Technology Department: Yue Chao

Technical Department Telephone:+86-22-26222775 ,+86 18602228435

QQ:1059237223   1611412939

Company Website:www.tjlhq.com

Enterprise E-mail:xzm@tjlhq.com

Company address: No.6, Zone B, South Jifeng Road, Hongcang City Industrial Park, Yanji Daohong, Beichen District, Tianjin

Tianjin Lingjie Transmission Technology Co., Ltd www.300.cn | SEO

Business License