The introduction of the precautions of the jaw electromagnetic clutch, come and collect!
Release time:
2022-08-22
What are the precautions for jaw electromagnetic clutch? Let's take a brief look at it. When using a jaw-type electromagnetic clutch, it is forbidden to add grease, otherwise the torque will be reduced. The electromagnetic clutch must be cleaned before installation to remove anti-rust grease and debris. The electromagnetic clutch can be installed coaxially or on a shaft. Must be fixed.
What are the precautions for jaw electromagnetic clutch? Let's take a brief look at it.
When operating the jaw-type electromagnetic clutch, it is forbidden to add grease, otherwise the torque will be reduced. The electromagnetic control clutch system must be cleaned before installation to remove anti-rust grease and debris. The electromagnetic clutch can be installed coaxially or on the shaft, and the axial direction must be fixed. There is no axial movement between the drive system components and the driven components. When the shaft is mounted on the shaft, the coaxiality between the active learning part and the driven mechanical part should not be greater than 0.lmm. When the wet electromagnetic control clutch is working, lubricating oil must be added to the friction plate materials. The lubrication management methods are:(1) Oil pouring lubrication;(2) Oil bath lubrication, some students immersed in oil are about 5 times the clutch volume;(3) Lubrication of axial oil supply system, different axial oil supply strategies should be used for high-speed and high-frequency information operation. When installing the cogged electromagnetic clutch, it is necessary to ensure that there is a certain gap between the end teeth so that grinding does not occur at idling speed, but it should not be greater than the value. The electromagnetically controlled clutch and brake are Class B insulated, and the normal temperature can be raised to 40°C. The operating temperature at the thermal equilibrium limit must not exceed 100 ° C, otherwise the coil and friction parts, power supply and control circuits may be damaged. The clutch power supply system is generally 24V DC (except for special handling order information). It can be obtained by effective step-down and full-wave rectifier system for three-phase or single-phase AC working voltage technology. There is no requirement for voltage stabilization and filtering. The power supply is more than 1.5 times the rated output power of the electromagnetic clutch. The half-wave rectifier power supply must be equipped with a freewheeling diode.
What is the operation method of the jaw electromagnetic clutch? Let's take a brief look at it.
1. Connect and disconnect action: If the drive part is installed between the start and the drive, there is no need for us to stop the innovation drive, but the start part will do the connection and disconnect action according to the necessary reaction force of the society.
2. Speed change: During operation, when the speed changes with each other, the clutch can be replaced without closing.
3. Positive and negative rotation: When the load point is switched between positive and negative rotation problems, the clutch system is used in conjunction with the operation of the driving system, so long as the students rotate forward.
4. High-frequency operation: Intermittent operation In a fast cycle, the switching frequency of the motor for repeated operation is limited, so the clutch is used to make it respond quickly and the braking accuracy is high.
5. Inching: When the machine starts to move and the position is engaged, only the clutch needs to be moved instantly.
What are the characteristics of the jaw electromagnetic clutch? Let's take a brief look at it.
1. High-speed development response: Because it is a dry type, the torque transmission speed is very fast, and more convenient actions can be achieved.
2. Strong durability: good heat dissipation, good material, even in high frequency, high energy use is also very durable.
3. Easy to assemble and maintain: It belongs to the static structure shape of the magnetic field through the coil hidden in a ball bearing, so it is easy for students to use, no need to take out our middle core or use carbon brush.
4. The action is true: the use of plate shrapnel, although there is strong vibration, but will not produce looseness, good durability.
Key words:
Jaw electromagnetic clutch
recommend News
The role of electromagnetic brake
2022-10-28
Regarding the difference between energized brakes and non-energized electromagnetic brakes, many users do not know the working principle of these two electromagnetic brakes and the difference between the two. Then, let's learn about the role of electromagnetic brakes!
Introduction and Application of Electromagnetic Brake
2022-10-18
Electromagnetic brakes are mainly matched with series motors and are widely used in the metallurgical industry. Construction. The chemical industry. Food. Machine tools. Phase. The elevator. Vessels. Packaging machinery and braking in the event of electrical failure.
The working principle of electromagnetic brake
2022-10-09
The electromagnetic brake is a connector that transmits torque from the active side to the passive side. Any combination of cutting or braking can be required. The electromagnetic brake has compact structure, simple operation, sensitive response and easy to realize remote control.
The company has a product research and development department composed of experts, senior engineers and other professional and technical personnel. It is engaged in research and development and has perfect research and development test equipment. At present, the products reach more than 100 series of nearly 1,000 specifications, and the force distance ranges from 0.1N. m ~ 250000N.m. The company has been rated as a high-tech enterprise by the state for more than ten consecutive years, and a number of R & D projects have been established locally and have received municipal financial support.
Service Hotline:
Sales Department: Xu Jie
Sales Phone:+86-22-26616372, +86-22-26341260, +86 13920613215
Fax: 86-022-26616580
Market Development Department: Li Shuo
Marketing Department Telephone:+86-22-26614130
Technology Department: Yue Chao
Technical Department Telephone:+86-22-26222775 ,+86 18602228435
QQ:1059237223 1611412939
Company Website:www.tjlhq.com
Enterprise E-mail:xzm@tjlhq.com
Company address: No.6, Zone B, South Jifeng Road, Hongcang City Industrial Park, Yanji Daohong, Beichen District, Tianjin