Israel DLM10 Series (EKE Series) Multi-disc Electromagnetic Clutch
Category:
Product Description
In order to ensure the uninterrupted operation of the electromagnetic clutch, it must be maintained and maintained frequently:
1. Always check the tightening degree of the bolts, especially tighten the bolts of the electromagnet, the bolts of the electromagnet and the housing, the bolts of the yoke, the bolts of the electromagnet coil and the terminal bolts.
2. Lubricant is often added to the movable part of the electromagnetic clutch.
3. Regularly check the mechanical wear of the movable parts, and remove the dust, flower hair and dirt on the surface of the electromagnet parts.
4. Regularly check the length of the armature stroke. This is because, during operation of the clutch, the stroke length of the armature will increase due to wear of the cutting surface. When the armature stroke length does not reach the normal value, it must be adjusted to restore the minimum gap between the braking surface and the turntable. If the armature stroke length is increased above the normal value, the suction force may be greatly reduced.
5. If the worn braking surface is replaced, the minimum clearance between the braking surface and the turntable should be properly adjusted.
During use, the electromagnetic clutch will have different failures due to various factors. The general failure of the electromagnetic clutch mostly occurs during starting, idling and load, but it occurs more often during the starting period, mainly manifested as failure to start, or the voltage input to the electromagnetic clutch is too low, and the regular input voltage is DC24V. As well as unstable power, slippage or high temperature, but there are also special circumstances.
Therefore, pay attention to the requirements when inputting the voltage. The elimination method is to detect whether the input voltage is the required voltage of the electromagnetic clutch. The coil is short-circuited, and this kind of fault is usually replaced or repaired. It is recommended to replace or modify the electromagnetic clutch circuit.
Main performance parameters
Main Technical Data
|
Specifications |
Rated dynamic torque |
Rated static moment |
no-load moment |
On time |
Disconnection time |
Rated voltage |
Coil power consumption (20 ℃) |
Maximum allowable speed |
Weight |
|
1A/1A.G |
12.5 |
20/14 |
0.088/0.05 |
0.14/0.11 |
0.03/0.025 |
24 |
26 |
3000 |
2 |
|
2A/2A.G |
25 |
40/27.5 |
0.175/0.10 |
0.18/0.14 |
0.032/0.028 |
24 |
27 |
3000 |
2.6 |
|
4A/4A.G |
40 |
63/44 |
0.280/0.16 |
0.20/0.18 |
0.04/0.03 |
24 |
33 |
3000 |
3.2 |
|
6A/6A.G |
63 |
100/70 |
0.350/0.26 |
0.25/0.20 |
0.045/0.04 |
24 |
43 |
3000 |
4 |
|
10A/10A.G |
100 |
160/110 |
0.500/0.35 |
0.28/0.25 |
0.06/0.045 |
24 |
43 |
3000 |
5.5 |
|
16A/16A.G |
160 |
250/175 |
1.00/0.56 |
0.30/0.28 |
0.08/0.06 |
24 |
47 |
2500 |
7.8 |
|
25A/25A.G |
250 |
400/280 |
1.50/0.88 |
0.35/0.30 |
0.11/0.08 |
24 |
55 |
2200 |
11 |
|
40A/40A.G |
400 |
630/440 |
2.50/1.40 |
0.40/0.35 |
0.12/0.11 |
24 |
62 |
2000 |
15 |
|
63A/63A.G |
630 |
1000/700 |
4.00/2.20 |
0.50/0.40 |
0.15/0.12 |
24 |
70 |
1750 |
21 |
|
100A/100A.G |
1000 |
1600/1100 |
6.00/3.00 |
0.60/0.50 |
0.18/0.15 |
24 |
79 |
1600 |
32 |
|
160A/160A.G |
1600 |
2500/1750 |
10/5.5 |
0.90/0.70 |
0.22/0.18 |
24 |
93 |
1350 |
50 |
|
250A/250A |
2500 |
4000/2750 |
15/8.6 |
1.15/0.90 |
0.28/0.25 |
24 |
110 |
1200 |
77 |
|
400A/400A.G |
4000 |
6300/4400 |
24/14 |
1.30/1.20 |
0.35/0.30 |
24 |
123 |
1000 |
122 |
|
630A.G |
6300 |
6800 |
22.5 |
2.1 |
0.4 |
24 |
137 |
900 |
194 |
|
1000A.G |
10000 |
11000 |
36 |
3.6 |
0.6 |
24 |
180 |
750 |
300 |
Note: G is dry multi-disc electromagnetic clutch
Note: G express the electromagnetic multidisc clutch of dry operation
Installation Schematic
Installation Diagram


Outline and installation dimensions
Shape and Installation Dimensions


|
Specifications |
Radial Dimensions |
Axial dimension |
Brush model |
|||||||||||||
|
|
D1 |
D2 |
D3 |
D4 |
Φ |
e |
h |
J |
K |
L |
L1 |
L2 |
L3 |
L4 |
E |
|
|
1A/ 1A.G |
100 |
100 |
85 |
50 |
18 |
50 0.025 |
19.9 0.14 |
2Xφ6 |
4XM6 |
45 |
42 |
5 |
5.5 |
8 |
0.30 |
wet Adopt DS-005 dry type Adopt DS-006 |
|
2A/ 2A.G |
110 |
110 |
90 |
55 |
20 |
60 0.025 |
22.3 0.14 |
2Xφ6 |
4XM6 |
48 |
45 |
5 |
5.5 |
8 |
0.30 |
|
|
4A/ 4A.G |
120 |
120 |
100 |
60 |
25 |
80 0.03 |
27.6 0.14 |
3Xφ6 |
6XM6 |
52 |
48 |
6 |
5.5 |
8 |
0.30 |
|
|
6A/6A.G |
132 |
132 |
105 |
65 |
30 |
80 0.03 |
32.6 0.17 |
3Xφ6 |
6XM8 |
55 |
50 |
7 |
5.5 |
8 |
0.30 |
|
|
10A/ 10A.G |
147 |
145 |
120 |
75 |
40 |
120 0.035 |
42.9 0.17 |
3Xφ8 |
6XM8 |
58 |
53 |
7 |
5.5 |
8 |
0.35 |
|
|
16A/ 16A.G |
162 |
160 |
135 |
85 |
45 |
140 0.035 |
48.3 0.17 |
3Xφ8 |
6XM8 |
62 |
57 |
7 |
5.5 |
8 |
0.40 |
|
|
25A/ 25A.G |
182 |
180 |
155 |
95 |
50 |
160 0.035 |
53.60 0.20 |
3Xφ10 |
6X M10 |
68 |
63 |
8 |
6 |
8 |
0.45 |
|
|
40A/ 40A.G |
202 |
200 |
170 |
120 |
60 |
180 0.035 |
64 0.20 |
3Xφ10 |
6X M10 |
76 |
70 |
9 |
6.25 |
8 |
0.50 |
|
|
63A/ 63A.G |
235 |
230 |
200 |
125 |
70 |
200 0.0435 |
74.3 0.20 |
3Xφ14 |
6X M12 |
86 |
80 |
10 |
6.25 |
8 |
0.60 |
|
|
100A/ 100A.G |
270 |
255 |
235 |
150 |
70 |
200 0.0435 |
74.3 0.20 |
3Xφ14 |
6X M12 |
100 |
92 |
12 |
8.5 |
10 |
0.70 |
|
|
160A/ 160A.G |
310 |
295 |
260 |
180H8 |
75 |
20±0.026 |
81.1 0.20 |
3Xφ16 |
6X M16 |
115 |
107 |
14 |
8 |
10 |
0.80 |
|
|
250A/ 250A.G |
360 |
340 |
305 |
200H8 |
100 |
28±0.026 |
106.4 0.20 |
3Xφ16 |
6X M16 |
132 |
122 |
15 |
8.5 |
10 |
0.90 |
|
|
400A/ 400A.G |
420 |
395 |
350 |
235H8 |
120 |
320 0.05 |
126.7 0.20 |
4Xφ20 |
6X M16 |
150 |
138 |
17 |
8.5 |
10 |
1 |
|
|
630A.G |
485 |
455 |
400 |
235 H8 |
130 |
32 0.01 0.07 |
136.7 0.20 |
4Xφ20 |
8X M20 |
172 |
157 |
20 |
10.5 |
12 |
1.1 |
|
|
1000A.G |
560 |
530 |
460 |
280 |
145 |
32±0.03 |
154.2 0.20 |
4Xφ25 |
4X M24 |
200 |
183 |
22 |
10.5 |
12 |
1.3. |
|
Note: 1. D3, J and K listed in the table are user connection dimensions, which are processed by the user. The data in this table are for reference only.
2.250A/250AG,400A/ 400A.G, 630A.G, 1000A.G,G is a double bond hole, the position is 180, h1 is 112.80 0.2,113.40 0.52,143.40 0.52,163.40 0.2
Remark:1. D3、J、K list in the list are sizes using for join of customer and processed by customer himself. The data of this list are for reference only
2. 250A/250AG,400A/ 400A.G、630A.G、1000A.G,G are double-Kay hole. The position in 180°,h1 is 112.8 plus0 0.2,133.4 plus0 0.52,143.4 plus0 0.52,163.4 plus0 0.2
The company has a product research and development department composed of experts, senior engineers and other professional and technical personnel. It is engaged in research and development and has perfect research and development test equipment. At present, the products reach more than 100 series of nearly 1,000 specifications, and the force distance ranges from 0.1N. m ~ 250000N.m. The company has been rated as a high-tech enterprise by the state for more than ten consecutive years, and a number of R & D projects have been established locally and have received municipal financial support.
Service Hotline:
Sales Department: Xu Jie
Sales Phone:+86-22-26616372, +86-22-26341260, +86 13920613215
Fax: 86-022-26616580
Market Development Department: Li Shuo
Marketing Department Telephone:+86-22-26614130
Technology Department: Yue Chao
Technical Department Telephone:+86-22-26222775 ,+86 18602228435
QQ:1059237223 1611412939
Company Website:www.tjlhq.com
Enterprise E-mail:xzm@tjlhq.com
Company address: No.6, Zone B, South Jifeng Road, Hongcang City Industrial Park, Yanji Daohong, Beichen District, Tianjin