Electromagnetic clutch failures generally occur during starting, idling and loading, but they often occur during starting, mainly because they cannot be started or the input voltage of the small electromagnetic clutch is too low. regular input voltage is DC24V. As well as unstable power supply, slippage or high temperature. However, there are special circumstances, so pay attention to the requirements when inputting voltage. The troubleshooting method is to check whether the input voltage is the voltage required by the small electromagnetic clutch. The coil is short-circuited, and this failure usually needs to be replaced or repaired. It is recommended to modify the small electromagnetic clutch circuit that is replaced or modified.
Unstable operation. It is likely that the input voltage is unstable. The power of the detection power supply is about 1.5 times greater than the rated power of the small electromagnetic clutch, and the voltage fluctuation is within-5%. The solution to unstable operation is to check the voltage and stabilize the voltage. Another case is friction heating, the coil is burned or short-circuited due to heat.
Basic usage of electromagnetic clutch
1. Connection and disconnection action: If a clutch is installed between the driving part and the starting part, there is no need to stop the driving part. The starting part will switch on and off according to the necessary reaction.
2. Variable speed: There is mutual variable speed during operation. At this time, when the clutch is used, the speed can be changed without turning off the drive.
3. Positive and reverse rotation: When the load point is switched between positive and reverse rotation, if it is used with the clutch, it only needs to be turned forward.
4. High-frequency operation: intermittent operation in a rapid cycle, repeated use of the ON and OFF of the motor provides a limited frequency, so the clutch is used to make it respond quickly and the braking accuracy is high.
5. Inching: When the machine starts to move and engages the position, it only needs to start the clutch instantly.
RL-02 electromagnetic clutch
Classification
Keyword
Robot special clutch
- Details
-
Electromagnetic clutch failures generally occur during starting, idling and loading, but they often occur during starting, mainly because they cannot be started or the input voltage of the small electromagnetic clutch is too low. regular input voltage is DC24V. As well as unstable power supply, slippage or high temperature. However, there are special circumstances, so pay attention to the requirements when inputting voltage. The troubleshooting method is to check whether the input voltage is the voltage required by the small electromagnetic clutch. The coil is short-circuited, and this failure usually needs to be replaced or repaired. It is recommended to modify the small electromagnetic clutch circuit that is replaced or modified.
Unstable operation. It is likely that the input voltage is unstable. The power of the detection power supply is about 1.5 times greater than the rated power of the small electromagnetic clutch, and the voltage fluctuation is within-5%. The solution to unstable operation is to check the voltage and stabilize the voltage. Another case is friction heating, the coil is burned or short-circuited due to heat.
Basic usage of electromagnetic clutch
1. Connection and disconnection action: If a clutch is installed between the driving part and the starting part, there is no need to stop the driving part. The starting part will switch on and off according to the necessary reaction.
2. Variable speed: There is mutual variable speed during operation. At this time, when the clutch is used, the speed can be changed without turning off the drive.
3. Positive and reverse rotation: When the load point is switched between positive and reverse rotation, if it is used with the clutch, it only needs to be turned forward.
4. High-frequency operation: intermittent operation in a rapid cycle, repeated use of the ON and OFF of the motor provides a limited frequency, so the clutch is used to make it respond quickly and the braking accuracy is high.
5. Inching: When the machine starts to move and engages the position, it only needs to start the clutch instantly.
Product inquiry
The company has a product research and development department composed of experts, senior engineers and other professional and technical personnel. It is engaged in research and development and has perfect research and development test equipment. At present, the products reach more than 100 series of nearly 1,000 specifications, and the force distance ranges from 0.1N. m ~ 250000N.m. The company has been rated as a high-tech enterprise by the state for more than ten consecutive years, and a number of R & D projects have been established locally and have received municipal financial support.
Service Hotline:
Sales Department: Xu Jie
Sales Phone:+86-22-26616372, +86-22-26341260, +86 13920613215
Fax: 86-022-26616580
Market Development Department: Li Shuo
Marketing Department Telephone:+86-22-26614130
Technology Department: Yue Chao
Technical Department Telephone:+86-22-26222775 ,+86 18602228435
QQ:1059237223 1611412939
Company Website:www.tjlhq.com
Enterprise E-mail:xzm@tjlhq.com
Company address: No.6, Zone B, South Jifeng Road, Hongcang City Industrial Park, Yanji Daohong, Beichen District, Tianjin