Share
- Details
-
Specifications
Rated transmission torque (N.m)
Rated voltage D.C(V)
Coil power consumption (20 ℃)
Maximum allowable combined speed
Maximum allowable speed
Weight
(kg)2A
20
24
17
60
5500
0.9
5A
50
24
22
50
4500
1.5
10A
100
24
28
30
4000
2.3
16A
160
24
32
30
3500
3.0
25A
250
24
44
20
3300
4.3
40A
400
24
58
10
3000
6.2
63A
630
24
60
Relatively stationary
2500
8.9
100A
1000
24
73
Relatively stationary
2200
14.0
160A
1600
24
87
Relatively stationary
2000
20.0
250A
2500
24
85
Relatively stationary
1700
34.0
The jaw type electromagnetic clutch installation note:
1. The electromagnetic clutch and brake are Class B insulation, the coil and friction parts are easily damaged, the normal temperature rises by 40, and the working temperature during thermal balance shall not exceed 100.
2. The power supply, control circuit and clutch power supply are usually 24 volts DC, which are obtained by step-down full-wave rectification of three-phase or single-phase AC voltage. Stability and filtering are not required. The power of the power supply is more than 1.5 times the rated power of the electromagnetic clutch.
Installation notes:
1. Please use the dry electromagnetic clutch without moisture, oil, etc. If moisture and oil are attached to the friction part, the friction torque will be greatly reduced. Therefore, in use, in order to avoid these situations, please install a cover.
2, please use the protective cover, when used in dusty places.
3. When installing the shaft, please use one of the keys specified in the JIS B1301-1959. For the long shaft size of the installation clutch, please use the standard JIS0401 H6 or JS6.
4. Please control the thrust of the installation shaft below 0.2MM, taking into account factors such as thermal expansion.
5. Please mechanically adjust the suction clearance within plus or minus 20% of the specified value for installation.
6. Please keep the bracket gently and do not suffer excessive pressure due to the bearing of the clutch.
7. Please use spring metal sheet, adhesive, etc. to prevent loosening. About the screws used for assembly.
8, with the mechanical side of the frame to maintain the wire at the same time, with the terminal plate and other reliable connection.
Maintenance and maintenance methods In order to ensure the continuous operation of the electromagnetic clutch, maintenance and maintenance must be carried out frequently:
1. Add more lubricant to the movable part of the electromagnetic clutch.
2. Check the stroke length of the armature regularly. This is because when the clutch is running, the wear of the section will increase the stroke length of the armature. It needs to be adjusted to restore the small gap between the braking surface and the turntable. When the stroke length does not reach the normal value, if the stroke length of the armature is above the normal value, the attraction force may be greatly reduced.
DLY4 jaw electromagnetic clutch
Classification
Keyword
Jaw electromagnetic clutch
- Details
-
Specifications
Rated transmission torque (N.m)
Rated voltage D.C(V)
Coil power consumption (20 ℃)
Maximum allowable combined speed
Maximum allowable speed
Weight
(kg)2A
20
24
17
60
5500
0.9
5A
50
24
22
50
4500
1.5
10A
100
24
28
30
4000
2.3
16A
160
24
32
30
3500
3.0
25A
250
24
44
20
3300
4.3
40A
400
24
58
10
3000
6.2
63A
630
24
60
Relatively stationary
2500
8.9
100A
1000
24
73
Relatively stationary
2200
14.0
160A
1600
24
87
Relatively stationary
2000
20.0
250A
2500
24
85
Relatively stationary
1700
34.0
The jaw type electromagnetic clutch installation note:
1. The electromagnetic clutch and brake are Class B insulation, the coil and friction parts are easily damaged, the normal temperature rises by 40, and the working temperature during thermal balance shall not exceed 100.
2. The power supply, control circuit and clutch power supply are usually 24 volts DC, which are obtained by step-down full-wave rectification of three-phase or single-phase AC voltage. Stability and filtering are not required. The power of the power supply is more than 1.5 times the rated power of the electromagnetic clutch.
Installation notes:
1. Please use the dry electromagnetic clutch without moisture, oil, etc. If moisture and oil are attached to the friction part, the friction torque will be greatly reduced. Therefore, in use, in order to avoid these situations, please install a cover.
2, please use the protective cover, when used in dusty places.
3. When installing the shaft, please use one of the keys specified in the JIS B1301-1959. For the long shaft size of the installation clutch, please use the standard JIS0401 H6 or JS6.
4. Please control the thrust of the installation shaft below 0.2MM, taking into account factors such as thermal expansion.
5. Please mechanically adjust the suction clearance within plus or minus 20% of the specified value for installation.
6. Please keep the bracket gently and do not suffer excessive pressure due to the bearing of the clutch.
7. Please use spring metal sheet, adhesive, etc. to prevent loosening. About the screws used for assembly.
8, with the mechanical side of the frame to maintain the wire at the same time, with the terminal plate and other reliable connection.
Maintenance and maintenance methods In order to ensure the continuous operation of the electromagnetic clutch, maintenance and maintenance must be carried out frequently:
1. Add more lubricant to the movable part of the electromagnetic clutch.
2. Check the stroke length of the armature regularly. This is because when the clutch is running, the wear of the section will increase the stroke length of the armature. It needs to be adjusted to restore the small gap between the braking surface and the turntable. When the stroke length does not reach the normal value, if the stroke length of the armature is above the normal value, the attraction force may be greatly reduced.
Product inquiry
The company has a product research and development department composed of experts, senior engineers and other professional and technical personnel. It is engaged in research and development and has perfect research and development test equipment. At present, the products reach more than 100 series of nearly 1,000 specifications, and the force distance ranges from 0.1N. m ~ 250000N.m. The company has been rated as a high-tech enterprise by the state for more than ten consecutive years, and a number of R & D projects have been established locally and have received municipal financial support.
Service Hotline:
Sales Department: Xu Jie
Sales Phone:+86-22-26616372, +86-22-26341260, +86 13920613215
Fax: 86-022-26616580
Market Development Department: Li Shuo
Marketing Department Telephone:+86-22-26614130
Technology Department: Yue Chao
Technical Department Telephone:+86-22-26222775 ,+86 18602228435
QQ:1059237223 1611412939
Company Website:www.tjlhq.com
Enterprise E-mail:xzm@tjlhq.com
Company address: No.6, Zone B, South Jifeng Road, Hongcang City Industrial Park, Yanji Daohong, Beichen District, Tianjin