1) Since the engagement and disengagement of the electromagnetic clutch are carried out at high speed, there will be many traces of clutch on the iron suction plate and the surface of the rotor. These marks are not hazardous to work and are permitted. 2) Apply a suitable voltage to the electromagnetic coil. For a 12V voltage electromagnetic coil, if it is added to a 6V voltage system, it cannot generate enough magnetic field, which will cause the suction iron to slip, shorten the life of the clutch, and reduce the cooling capacity. Conversely, if a 6V coil is added to a 12V voltage system, the coil life will be shortened. 3) The gap between the coil and the rotor is very important. The coil and the rotor should be as close as possible to obtain a stronger magnetic field, but the gap should not be too small to prevent the rotor from dragging the coil (for the fixed-ring clutch). 4) The gap between the rotor and the suction iron is also very important. If this gap is too small, the rotor will drag the suction iron when the clutch is disengaged. However, if the gap is too large, there is too little contact between them when the clutch is operated. Both of these conditions can cause poor clutch performance. The reasonable gap between them should be that when the clutch has no current, the two do not drag; when the clutch has current, it can ensure that no slippage occurs.
1. Please use the dry electromagnetic clutch when there is no moisture, oil, etc. If the friction part is stained with moisture or oil, the friction torque will be greatly reduced, and the sensitivity of the clutch will also become worse. To avoid these situations in use, please add a cover. 2. Please use a protective cover when using it in a place with a lot of dust. 3. Please use JIS0401 H6 or JS6 for the long axis size of the clutch. Use one of the keys specified in the JIS B1301-1959 for mounting the shaft. Taking into account the thermal expansion and other factors, the thrust of the installation shaft should be selected below 0.2MM. 5. During installation, please adjust the suction gap mechanically to within plus or minus 20% of the specified value. 6. Please keep the bracket light and do not use the bearing of the clutch to bear excessive pressure. 7. For the screws used for assembly, please use spring metal sheet, adhesive, etc. to prevent loosening. 8, the use of the mechanical side of the frame to maintain the lead at the same time, but also the use of terminal plates and other real connection.
Main performance parameters
Main Technical DataSpecifications
ModelRated dynamic torque
Rated Torque
N.MRated static moment
Rated Static Torque
N.MRated voltage
Rated Voltage
D.C.VCoil power consumption (20 ℃)
CoilPower (20℃)WDLMS-16A
160
176
24
38
Note: use brush model: DS-005
Note:Brush model:DS-005
DLMS-16A two-way electromagnetic clutch
Classification
Keyword
Multi-disc electromagnetic clutch
- Details
-
1) Since the engagement and disengagement of the electromagnetic clutch are carried out at high speed, there will be many traces of clutch on the iron suction plate and the surface of the rotor. These marks are not hazardous to work and are permitted. 2) Apply a suitable voltage to the electromagnetic coil. For a 12V voltage electromagnetic coil, if it is added to a 6V voltage system, it cannot generate enough magnetic field, which will cause the suction iron to slip, shorten the life of the clutch, and reduce the cooling capacity. Conversely, if a 6V coil is added to a 12V voltage system, the coil life will be shortened. 3) The gap between the coil and the rotor is very important. The coil and the rotor should be as close as possible to obtain a stronger magnetic field, but the gap should not be too small to prevent the rotor from dragging the coil (for the fixed-ring clutch). 4) The gap between the rotor and the suction iron is also very important. If this gap is too small, the rotor will drag the suction iron when the clutch is disengaged. However, if the gap is too large, there is too little contact between them when the clutch is operated. Both of these conditions can cause poor clutch performance. The reasonable gap between them should be that when the clutch has no current, the two do not drag; when the clutch has current, it can ensure that no slippage occurs.
1. Please use the dry electromagnetic clutch when there is no moisture, oil, etc. If the friction part is stained with moisture or oil, the friction torque will be greatly reduced, and the sensitivity of the clutch will also become worse. To avoid these situations in use, please add a cover. 2. Please use a protective cover when using it in a place with a lot of dust. 3. Please use JIS0401 H6 or JS6 for the long axis size of the clutch. Use one of the keys specified in the JIS B1301-1959 for mounting the shaft. Taking into account the thermal expansion and other factors, the thrust of the installation shaft should be selected below 0.2MM. 5. During installation, please adjust the suction gap mechanically to within plus or minus 20% of the specified value. 6. Please keep the bracket light and do not use the bearing of the clutch to bear excessive pressure. 7. For the screws used for assembly, please use spring metal sheet, adhesive, etc. to prevent loosening. 8, the use of the mechanical side of the frame to maintain the lead at the same time, but also the use of terminal plates and other real connection.
Main performance parameters
Main Technical DataSpecifications
ModelRated dynamic torque
Rated Torque
N.MRated static moment
Rated Static Torque
N.MRated voltage
Rated Voltage
D.C.VCoil power consumption (20 ℃)
CoilPower (20℃)WDLMS-16A
160
176
24
38
Note: use brush model: DS-005
Note:Brush model:DS-005
Product inquiry
The company has a product research and development department composed of experts, senior engineers and other professional and technical personnel. It is engaged in research and development and has perfect research and development test equipment. At present, the products reach more than 100 series of nearly 1,000 specifications, and the force distance ranges from 0.1N. m ~ 250000N.m. The company has been rated as a high-tech enterprise by the state for more than ten consecutive years, and a number of R & D projects have been established locally and have received municipal financial support.
Service Hotline:
Sales Department: Xu Jie
Sales Phone:+86-22-26616372, +86-22-26341260, +86 13920613215
Fax: 86-022-26616580
Market Development Department: Li Shuo
Marketing Department Telephone:+86-22-26614130
Technology Department: Yue Chao
Technical Department Telephone:+86-22-26222775 ,+86 18602228435
QQ:1059237223 1611412939
Company Website:www.tjlhq.com
Enterprise E-mail:xzm@tjlhq.com
Company address: No.6, Zone B, South Jifeng Road, Hongcang City Industrial Park, Yanji Daohong, Beichen District, Tianjin