Electromagnetic brake is an additional device commonly used in motors, and there are two types of power-on braking and power-off braking. The electrified braking method is fast and accurate in positioning, and is used for automatic intelligent control equipment that requires precise positioning. The application occasions have certain limitations; electromagnetic brakes are widely used, and mechanical transmission systems with positioning and braking requirements such as machine tools, metallurgy, motors, chemicals, construction, packaging and printing, textiles, and automatic production lines are widely used. In addition to the advantages of convenient control and fast braking speed, loss of power braking means that the equipment can be safely braked under the condition of unexpected power failure and out of control to ensure the safety of personnel and facilities.
The electromagnetic power-off brake is mainly composed of a yoke equipped with a coil, an armature, a connecting plate, a spring, a friction disc, a gear sleeve and other parts. The spring is installed in the yoke, and the armature can move in the axial direction. The yoke is fixed on the base by mounting screws to adjust the clearance. After the specified value is reached, the gear sleeve is connected with the transmission shaft through a key, and the outer teeth of the gear sleeve mesh with the inner teeth of the friction plate.
When the coil is de-energized, under the action of the spring force, the friction disc and the armature and the base (or connecting plate) generate friction, and the drive shaft is braked through the gear sleeve. When the coil is energized, under the action of electromagnetic force, The armature is attracted to the magnetic yoke, which releases the friction disc and releases the brake.
The choice of the type of electromagnetic brake depends to a large extent on the size of the braking torque required. In addition, the braking moment of inertia, relative speed, braking time, operating frequency and other factors should also be considered. The following is a brake manufacturer's recommend modeling rules, different manufacturers will be slightly different, but the principles are similar.This series is a jaw brake. This brake is a double output structure brake, one end is a pulley output, and the other end is an encoder mounting shaft output. This brake is an integral structure, easy to install.
Main performance parameters
Main Technical DataSpecifications
SizeRated transmission torque
Rated Transmitting Torque
N.MRated voltage
Rated Voltage
D.C.VCoil power consumption (20 ℃)
Coil Consumption power(20℃)Maximum allowable combined speed
Max Engagement
Revolution
r/minMaximum allowable speed
Allowed
Max Revolution
r/minDZY0-16D
160
24
24
50
2000
DZY0-16D jaw electromagnetic brake
Classification
Keyword
Gate control system clutch
- Details
-
Electromagnetic brake is an additional device commonly used in motors, and there are two types of power-on braking and power-off braking. The electrified braking method is fast and accurate in positioning, and is used for automatic intelligent control equipment that requires precise positioning. The application occasions have certain limitations; electromagnetic brakes are widely used, and mechanical transmission systems with positioning and braking requirements such as machine tools, metallurgy, motors, chemicals, construction, packaging and printing, textiles, and automatic production lines are widely used. In addition to the advantages of convenient control and fast braking speed, loss of power braking means that the equipment can be safely braked under the condition of unexpected power failure and out of control to ensure the safety of personnel and facilities.
The electromagnetic power-off brake is mainly composed of a yoke equipped with a coil, an armature, a connecting plate, a spring, a friction disc, a gear sleeve and other parts. The spring is installed in the yoke, and the armature can move in the axial direction. The yoke is fixed on the base by mounting screws to adjust the clearance. After the specified value is reached, the gear sleeve is connected with the transmission shaft through a key, and the outer teeth of the gear sleeve mesh with the inner teeth of the friction plate.
When the coil is de-energized, under the action of the spring force, the friction disc and the armature and the base (or connecting plate) generate friction, and the drive shaft is braked through the gear sleeve. When the coil is energized, under the action of electromagnetic force, The armature is attracted to the magnetic yoke, which releases the friction disc and releases the brake.
The choice of the type of electromagnetic brake depends to a large extent on the size of the braking torque required. In addition, the braking moment of inertia, relative speed, braking time, operating frequency and other factors should also be considered. The following is a brake manufacturer's recommend modeling rules, different manufacturers will be slightly different, but the principles are similar.This series is a jaw brake. This brake is a double output structure brake, one end is a pulley output, and the other end is an encoder mounting shaft output. This brake is an integral structure, easy to install.
Main performance parameters
Main Technical DataSpecifications
SizeRated transmission torque
Rated Transmitting Torque
N.MRated voltage
Rated Voltage
D.C.VCoil power consumption (20 ℃)
Coil Consumption power(20℃)Maximum allowable combined speed
Max Engagement
Revolution
r/minMaximum allowable speed
Allowed
Max Revolution
r/minDZY0-16D
160
24
24
50
2000
Product inquiry
The company has a product research and development department composed of experts, senior engineers and other professional and technical personnel. It is engaged in research and development and has perfect research and development test equipment. At present, the products reach more than 100 series of nearly 1,000 specifications, and the force distance ranges from 0.1N. m ~ 250000N.m. The company has been rated as a high-tech enterprise by the state for more than ten consecutive years, and a number of R & D projects have been established locally and have received municipal financial support.
Service Hotline:
Sales Department: Xu Jie
Sales Phone:+86-22-26616372, +86-22-26341260, +86 13920613215
Fax: 86-022-26616580
Market Development Department: Li Shuo
Marketing Department Telephone:+86-22-26614130
Technology Department: Yue Chao
Technical Department Telephone:+86-22-26222775 ,+86 18602228435
QQ:1059237223 1611412939
Company Website:www.tjlhq.com
Enterprise E-mail:xzm@tjlhq.com
Company address: No.6, Zone B, South Jifeng Road, Hongcang City Industrial Park, Yanji Daohong, Beichen District, Tianjin